Lintel Testing for Reduced Shear Reinforcement in Insulating Concrete Form Systems (May 1998, 21 p.)

Send URL to FriendSend this to a friend
ORDER

FULL TEXT:
* Adobe Acrobat (*.pdf, 870 KB)

The purpose of this test program is to investigate the structural capacity and performance of the concrete lintels typically used in ICF construction. Lintels are reinforced concrete structural elements that support loads above openings in concrete walls. In the Prescriptive Method lintel spans were calculated using the Building Code Requirements for Reinforced Concrete (ACI 318-95) [2]. According to ACI 318-95, shear reinforcement is required for all ICF lintels in the Prescriptive Method. Shear reinforcement is generally difficult to install in ICF systems and, therefore, adds to the construction costs.

Results from this research program indicate that shear reinforcement for the ICF lintels in the Prescriptive Method is overly conservative and may be eliminated without sacrificing performance in span less than about 4 ft. (1.2 m). Consequently, future modifications to the Prescriptive Method and ACI 318-95 should be considered to result in more efficient utilization of ICFs in residential construction. Additional experimental and analytical work is recommended to expand this cost-effective benefit to ICF lintels that are longer in span.



spacer

Content updated on 08/24/07   Back to Top Back to Top
 If you do not have the Adobe Acrobat Reader program already installed on your computer to view PDF files, CLICK HERE to download the free reader.
HUD logo HUD USER, P.O. Box 23268, Washington, DC 20026-3268
Toll Free: 1-800-245-2691 TDD: 1-800-927-7589
Local: 1-202-708-3178 Fax: 1-202-708-9981
Home Icon
HUD USER Home
Privacy Statement